Highlights: 

FASTER data collection for DCX and DCA-60 data collectors

ALERT running in DCX and DCA60 has been optimized to significantly reduce data collection time. Typical* machine measurement times have been reduced by 30-65%.  *Learn More

 

New User Defined Point Capabilities

User-defined points (UDPs) may now be defined at the plant or area levels of the database hierarchy. By allowing UDPs at the plant or area level, reports covering groups of machines now have a home in the database tree. UDPs are now also replicated between master and subscription databases.

Integration of WATCHMAN Reliability Portal™

New features allow customers to access test results and analyst reports through the WATCHMAN Reliability Portal on the Web. Portal users can configure email reminders to let them know when data collection is due or when new reviewed results are available.

Microsoft Windows 7 Support

ExpertALERT now supports the Windows 7 Operating System.

New "Quick Review" of expert system automated analysis

Un-reviewed results can now be automatically screened based on severity level by selecting this option from the Expert menu.

New Support for Single-axis Sensors

A new data collector option lets you change triaxial to single-axis mode so a user can collect multi-axis data with a single-axis sensor.

New Fine Tune Calibration Settings for Triaxial Sensors

A new data collector option lets you specify individual sensitivity settings for all three accelerometers within your triaxial sensor, allowing for more accurate data collection.

Many Usability Enhancements

Thanks to feedback from our analysts and customers, many updates have been made to improve the performance and usability of ExpertALERT. 

 

To get your new 3.40 version of ExpertALERT, StandardALERT, ViewALERT, or embedded (data collector) ALERT, click on the button below:



ExpertALERT Training Conference Houston, Texas 

This three-day course is intended for personnel who are new to the vibration program or require a refresher of the basic methodology implemented in the ExpertALERT software.

The focus of the course will be on setting up your system, including machine blocking, sensor orientation and creation of the database. You will also see the fundamentals of data collections. 

On completion of this course you should be able to set up the database for general machines, collect quality and repeatable data, review the vibration spectra and print automated diagnostic reports. With these skills you will be ready to begin learning all the things necessary to become a proficient vibration analyst.

Dates:

May 18, 2010 to May 20, 2010 -  8:30 a.m. to 5:00 p.m.  

For more information and to register, click here


ExpertALERT 3.40 Cocktail Reception – Houston, Texas

Come to Houston on May 20th, 4:30 PM for a cocktail reception and see what is new with Azima DLI and ExpertALERT 3.40. 

See the new features of EA 3.40 

Demo Azima DLI eLearning

Chat with others about programs 

Discuss Synthesized Baseline

Learn about Azima DLI solutions 

See the new Sprite Roamer™

For more information and to register, click here  


Have Questions... Call Us Today!

If you have questions about how to upgrade to the best ExpertALERT ever, call our sales specialists at 800-654-2844 ext. 3 or international at (+1) 206-842-7656 ext. 3 from 8:00 AM to 5:00 PM (GMT-8), Monday to Friday.   After hours or weekends, email us at sales@AzimaDLI.com and we will be happy to assist you.

 


Azima DLI World Headquarters
300 Trade Center - Suite 4610 - Woburn, MA 01801 - U.S.A.
toll free 800-482-2290 - p. 781-938-0707 - f: 781-935-0179

KNOWING WHAT'S AHEAD™

www.AzimaDLI.com

© 2010 - Azima DLI - All rights reserved.

 


About Azima DLI

Azima DLI is the leader and premier provider of predictive machine condition monitoring and analysis services that align with customers' high standards for reliability, availability and uptime. Azima DLI's WATCHMAN™ Reliability Services utilize flexible deployment models, proven diagnostic software and unmatched analytical expertise to deliver sustainable, scalable and cost-effective condition-based maintenance programs. The company's bundled solutions enable customers to choose comprehensive, proven programs that ensure asset availability and maximize productivity. Azima DLI is headquartered in Woburn, Massachusetts with offices across the U.S. and international representation in Asia-Pacific, Central America, Europe and South America. For more information, call +1 (800) 482-2290 or visit http://www.azimadli.com

 

*Typical Machine Test Time

Freq. Ranges (Hz)

Axes Collected

FFT1

Time Domain


Amplitude Demodulation2

Pre v.3.40
Collect Time (sec)

v.3.40
Collect Time (sec)

% Improvement

100, 1000

A, R, T

x

x

x

84

59

30%

200, 2000

A, R, T

x

x

x

52

31

40%

300, 3000

A, R, T

x

x

x

37

19

49%

500, 5000

A, R, T

x

x

x

35

16

54%

1000, 10000

A, R, T

x

x

x

29

10

65%

Notes:  
1 - FFT settings:  800 lines, 50% overlap, 4 averages
2 - Default amplitude demodulation data collection settings